Serra de l'Ebre

Needs attention

Catalonia · Wind · 57 MW installed · 5 technicians · manager Firas Cheaib

Output now

14.1 MW

Load factor

25 %

Energy today

34 MWh

Availability

96.6 %

Producing

9 / 13

Open alarms

6

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

5.9 m/s ENE

Irradiance

0 W/m²

Temperature

16.3 °C

Cloud cover

79 %

Conditions

Overcast

Substation

Ascó SE 400 kV

Voltage

400.2 kV

Frequency

49.970 Hz

Power factor

0.987

Curtailment

8 %

Day-ahead price

91.15 €/MWh

Assets

13 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Nordex N163/5.X · 5.0 MW

Maintenance
0%

Output

0.00 MW

Today

1.5 MWh

Wind

11.8 m/s

Wind turbine

WTG-02

Nordex N163/5.X · 5.0 MW

Producing
34%

Output

1.67 MW

Today

3.6 MWh

Wind

9.0 m/s

Wind turbine

WTG-03

Siemens Gamesa SG 5.0-145 · 6.2 MW

Producing
21%

Output

1.29 MW

Today

2.8 MWh

Wind

7.9 m/s

Wind turbine

WTG-04

Siemens Gamesa SG 5.0-145 · 5.0 MW

Producing
3%

Output

0.14 MW

Today

4.9 MWh

Wind

5.3 m/s

Wind turbine

WTG-05

Siemens Gamesa SG 6.6-170 · 6.2 MW

Maintenance
0%

Output

0.00 MW

Today

1.9 MWh

Wind

3.2 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
53%

Output

2.63 MW

Today

4.4 MWh

Wind

10.2 m/s

Wind turbine

WTG-07

Siemens Gamesa SG 5.0-145 · 5.0 MW

Standby
0%

Output

0.00 MW

Today

5.3 MWh

Wind

7.3 m/s

Wind turbine

WTG-08

Nordex N149/4.0-4.5 · 5.0 MW

Producing
69%

Output

3.47 MW

Today

2.4 MWh

Wind

10.9 m/s

Wind turbine

WTG-09

Siemens Gamesa SG 6.6-170 · 6.2 MW

Curtailed
40%

Output

2.47 MW

Today

2.4 MWh

Wind

11.7 m/s

Wind turbine

WTG-10

Siemens Gamesa SG 6.6-170 · 4.2 MW

Producing
20%

Output

0.84 MW

Today

2.2 MWh

Wind

8.0 m/s

Wind turbine

WTG-11

Vestas V162-6.2 · 4.2 MW

Producing
39%

Output

1.62 MW

Today

2.7 MWh

Wind

9.3 m/s

Inverter skid

INV-01

Sungrow SG3125HV-MV · 4.6 MVA

Producing
34%

Output

1.58 MW

Today

8.5 MWh

Availability

99.5 %

Inverter skid

INV-02

SMA Sunny Central 4600 UP · 3.1 MVA

Producing
95%

Output

2.95 MW

Today

3.7 MWh

Availability

96.3 %

Alarms
Site alarms
Most recent events from this site's assets.

Blade ice detected

WTG-09· 11-05 23:20
Medium

Generator winding temperature high

WTG-01· 11-05 17:09
Medium

Yaw misalignment above limit

WTG-05· 11-05 16:01
Low

Pitch system hydraulic pressure low

WTG-02· 11-05 11:43
Medium

Cooling fan failure

INV-01· 11-05 09:03
Low

Service interval exceeded

WTG-06· 11-05 07:48
Medium